Engineering the Assistant-Port-Free Hysterectomy
Video Title: Engineering the Assistant-Port-Free Hysterectomy
Primary Contact: Dr. Gaurav S. Desai
Institution: P. D. Hinduja Hospital and Research Centre, Mumbai, India
Email: gdesai83@gmail.com

Purpose
The assistant port is traditionally used to provide suction, traction and facilitate suture delivery during complex robotic hysterectomy. We hypothesised that these functions could be redesigned into the surgical workflow, permitting complete hysterectomy without an accessory port even in a large, anatomically distorted benign uterus.

Methods
A 58-year-old woman with post-menopausal bleeding and a markedly enlarged uterus due to diffuse adenomyosis and multiple 3–8 cm intramural and subserosal fibroids underwent robotic total hysterectomy with bilateral salpingo-oophorectomy using the da Vinci Xi platform. Three robotic ports were used, with no assistant or accessory port. The technique incorporated precise 8–10 cm port spacing, early bilateral devascularisation, retrograde dissection when the uterine pedicle was obscured, dynamic V-shaped uterine manipulation, and transcolpotomy introduction of the vault suture.

Results
The procedure was completed entirely robotically without an assistant port or conversion. Operative time was 75 minutes, including 15 minutes for specimen retrieval, with minimal estimated blood loss. The enlarged uterus, tubes and ovaries were removed vaginally without power morcellation. Vault closure was completed robotically using the suture introduced through the colpotomy. The patient resumed oral intake within 24 hours, mobilised within 12 hours and was discharged at 48 hours without complications.

Conclusions
This case demonstrates a workflow-engineering approach to eliminating the assistant port rather than reducing ports. Strategic port geometry, vascular-first dissection, retrograde pedicle control, dynamic manipulation and transcolpotomy suture delivery collectively replace functions conventionally assigned to an assistant. The technique preserves robotic dexterity while reducing abdominal access and may offer a reproducible pathway toward assistant-port-free robotic hysterectomy.