712: 3D-AR and Confocal Microscopy Guidance During Robotic Prostatectomy- Enrico Checcucci
This is one of the entries accepted for adjudication for the 2026 KS Innovation Awards, sponsored by the Vattikuti Foundation. Posting here does not imply being a Finalist.
Here is the Abstract:
3D-AR AND CONFOCAL MICROSCOPY GUIDANCE DURING ROBOTIC
PROSTATECTOMY
Presenting: E. Checcucci, MD, MSc
Division of Urology – iNOC – Istituto Nazionale Oncologico Candiolo, IRCCS, Candiolo (TO), Italy
Email: checcu.e@hotmail.it
Purpose
To evaluate the feasibility and diagnostic accuracy of an integrated intraoperative workflow combining three-dimensional augmented reality (3D-AR) guidance and real-time digital histological assessment to support patient-specific nerve-sparing during robot-assisted radical
prostatectomy (RARP).
Methods
Twenty-seven patients undergoing RARP were prospectively treated using a 3D-AR guided approach. Preoperative imaging was processed to generate patient-specific 3D models of the prostate, tumor, and surrounding anatomical structures, which were integrated into the robotic surgical field through augmented reality. During nerve-sparing dissection, selective biopsies were obtained from the preserved neurovascular bundles at areas considered at higher oncological risk
based on preoperative imaging and intraoperative 3D guidance. Specimens were assessed intraoperatively using the HISTOLOG real-time digital pathology system. Histological findings were compared with final pathological examination of the prostatectomy specimen to evaluate diagnostic performance and concordance.
Results
Intraoperative HISTOLOG assessment was successfully performed in all patients. Compared with final pathology, the technique showed a sensitivity of 100% and a negative predictive value of
100% for the identification of tumor involvement adjacent to the preserved neurovascular bundle. Overall diagnostic concordance was approximately 90%. One false-positive result was observed,
while no false-negative findings occurred. Negative intraoperative assessment therefore reliably excluded tumor involvement in the examined nerve-sparing margins and supported preservation of
the neurovascular bundles without compromising immediate oncological decision-making.
Conclusions
The integration of 3D-AR guidance with real-time digital histological assessment provides a novel intraoperative strategy for tailoring nerve-sparing during RARP. By combining patient-specific
anatomical navigation with immediate tissue characterization, this approach may allow preservation of the neurovascular bundles when oncologically appropriate while providing real-time support for
surgical decision-making. Further validation in larger prospective cohorts is warranted.