714: Robotic Hepatectomy for Hepatoblastoma in a 5-kg Infant- Ankur Mandalia
This is one of the entries accepted for adjudication for the 2026 KS Innovation Awards, sponsored by the Vattikuti Foundation. Posting here does not imply being a Finalist.
Producer / Presenting Surgeon:
Dr. Ankur Mandelia, Professor,
Department of Pediatric Surgery,
Sanjay Gandhi Post Graduate Institute of Medical Sciences (SGPGIMS),
Lucknow-226014, India
Tel: +91 8004967729, +91 0522 2495668
e-mail: drankurmandelia@gmail.com
ORCID ID: https://orcid.org/0000-0002-2270-9948
Title: Robotic Hepatectomy for Hepatoblastoma in a 5-kg Infant
Subtitle: Navigating Surgical Challenges in a Limited Working Space
Purpose: To demonstrate the technical challenges and innovative adaptations enabling robotic left lateral sectionectomy for hepatoblastoma in a 6-month-old, 5-kg infant.
Methods: A 6-month-old boy with hepatoblastoma involving segments II, III, IV and VIII with caudate involvement (PRETEXT III) received four cycles of neoadjuvant PLADO chemotherapy. Following treatment, disease was localized to segments II and III (POSTTEXT I). Robotic left lateral sectionectomy was performed using the da Vinci Xi robotic system. The extremely small abdominal cavity presented significant challenges, with limited working space and restricted instrument manoeuvrability. A laparoscopic CUSA introduced through the
assistant port was used for controlled parenchymal transection, complementing the robotic instruments. The left hepatic vein was divided using a robotic vascular stapler, demonstrating the ability to perform precise vascular control within the confined operative field.
Results: The procedure was completed uneventfully. Operating time was 525 minutes, with blood loss of 60 mL. Histopathology demonstrated a 2.5 × 2 × 2 cm unifocal epithelial hepatoblastoma with fetal pattern and tumor-free resection margins. Full oral feeds were achieved by postoperative day 3, and the child was discharged on day 6. At 3 months, he remained asymptomatic, with normal liver function tests, AFP of 8 ng/mL, and no radiological evidence of recurrence.
Conclusions: Robotic liver resection in a 5-kg infant requires adaptation to severe spatial constraints. Combining robotic precision and articulation with assistant-port CUSA parenchymal transection and robotic stapling provided complementary solutions to the technical
challenges of infant hepatic resection.