788: Robotic-Assisted Myomectomy for High Fibroid Burden- Eriica Stockwell

This is one of the entries accepted for adjudication for the 2026 KS Innovation Awards, sponsored by the Vattikuti Foundation. Posting here does not imply being a Finalist.

Here is the Abstract:
Feasibility and Safety of Robotic-Assisted Myomectomy in Patients With High Fibroid Burden

Purpose:
Patients with high uterine fibroid burden are frequently directed toward open surgery because of concerns regarding operative complexity, blood loss, and uterine reconstruction. Emerging technologies, including patient-specific three-dimensional (3D) modeling and advanced robotic instrumentation, may expand the feasibility of minimally invasive management in these challenging cases. We evaluated the safety and feasibility of robotic-assisted myomectomy in patients traditionally considered candidates for laparotomy.

Methods:
We performed a retrospective case series of patients undergoing robotic-assisted myomectomy over a 5-year period at a single tertiary academic center. Inclusion criteria required removal of More than or equal to-10 fibroids. Preoperative MRI studies were segmented to generate patient-specific 3D uterine and fibroid models, which were displayed intraoperatively using TilePro® on the da Vinci robotic console to assist surgical planning and fibroid localization. Outcomes included fibroid number, maximum fibroid diameter, specimen weight, estimated blood loss (EBL), operative time, conversion to laparotomy, transfusion, reoperation, length of stay, and perioperative complications.

Results:
Sixty-one patients met inclusion criteria. Median fibroid number was 17 (range 10-65), median maximum diameter was 7.4 cm (range 1.0-22.5 cm), and median specimen weight was 329 g (range 5-1440 g). No cases required conversion to laparotomy. Median EBL was 150 mL (range 20-1600 mL), and median operative time was 212 minutes (range 95-402 minutes). Increasing fibroid burden correlated with greater EBL based on fibroid number (ρ=0.382, p=0.002), specimen weight (ρ=0.560, p less than 0.001), and maximum diameter (ρ=0.393, p=0.002). Operative time correlated with fibroid number (ρ=0.464, p less than 0.001). Transfusion occurred in 9.8% of patients, and one patient (1.6%) required reoperation for postoperative bleeding unrelated to the myomectomy site. Most patients were discharged on postoperative day 0 or 1.

Conclusions:
Robotic-assisted myomectomy is feasible and safe in selected patients with high fibroid burden, achieving a 0% conversion rate and low myomectomy-related morbidity despite substantial surgical complexity. Integration of MRI-derived patient-specific 3D models through TilePro visualization, combined with enhanced robotic visualization, articulating instrumentation, and advanced suturing capability, may facilitate minimally invasive management of cases traditionally treated by laparotomy.